RODI 50GPD Installation Instruction

How to Install your PURE N SAFE 4 Stage RODI system

 

4 stage RO Portable3

 

 

 

 

Installation Instructions:

20160321_212903

 

Remove the small blue clamp on the RO membrane housing inlet tube
20160321_212915

 

Push the collet

20160321_213019

While holding the collet, pull the tube out

 

20160321_213035

 

 

 

 

 

20160321_213108

Open the membrane housing cap

 

20160321_213116

 

 

 

 

 

 

Watch the direction

20160321_213122

 

Insert the membrane inside the membrane housing

 

20160321_213126

 

 

Put the membrane cap back

 

20160321_213139

Tight using the membrane spanner

 

20160321_213150

 

 

 

 

 

Place the tube inside the fitting and push inside

 

20160321_213204

 

 

 

Place the clip back in place

 

 

Now the system a prepared for connection

IMG_7698

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Locate the cold water connection where you want to connect the system to

 

IMG_7703

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove the existing connection

 

IMG_7704

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw the system inlet connection

 

IMG_7706

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reconnect the water connection to the system inlet connection

 

IMG_7707

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insert the inlet valve

 

20160321_213313

 

 

Insert the 1/4’ tube to the other side of the inlet valve

 

20160321_213404

Remove the clamp and the plug from the inlet to the system

 

20160321_213324

 

 

Use scissors or a cutter

 

20160321_213333

 

 

 

 

Make sure the tube is square and free of sharp edges

 

20160321_213418

 

 

Insert the tube to the inlet water side in to the system

 

20160321_21343320160321_213441

Insert another tube to the product water (Pure Water)

The other side of this tube will be used to collect the Ultra-pure Water for your fish tank

 

20160321_213521

 

 

Remove the pug in the drain line

 

20160321_213527

 

 

Connect another tube length to the drain outlet connection on the system

Use this tube to collect the wastewater from the system

This water is high in salt, you can use for irrigation, washing machine or wash down. Other option, through to sewer

?

PURE N SAFE RODI Ready system

 

 

Now your filter is connected and ready

Open the water inlet valve

Flush the system for about an hour to remove preservation chemical from the system

Check the TDS with your TDS pin

Use the water for your fish tank once the TDS or conductivity is below 10.
Please feel free to post you questions or comments

No Comments Yet.

Leave a comment